American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 4 / Number 2P3

FED Pumped Limiter Configuration Issues

J. R. Haines, G. M. Fuller

Fusion Science and Technology / Volume 4 / Number 2P3 / September 1983 / Pages 1004-1009

Impurity Control and Vacuum Technology / dx.doi.org/10.13182/FST83-A22990

Impurity control in the Fusion Engineering Device (FED) is provided by a toroidal belt pumped limiter. Limiter design issues addressed in this paper are (1) poloidal location of the limiter belt, (2) shape of the limiter surface facing the plasma, and (3) whether the belt is pumped from one or both sides. The criteria used for evaluation of li.miter configuration features were sensitivity to plasma edge conditions and ease of maintenance and fabrication. The evaluation resulted in the selection of a baseline FED limiter that is located at the bottom of the device and has a flat surface with a single leading edge.