Fusion Science and Technology / Volume 3 / Number 1 / January 1983 / Pages 137-143
Technical Paper / Magnet System / dx.doi.org/10.13182/FST83-A20824
Articles are hosted by Taylor and Francis Online.
Coil misalignments in quadrupole tandem mirrors generate dipole and quadrupole field errors. The effects of these errors on the magnetic field are calculated. Misalignments in the thin, quadrupole fans have particularly large effects on field lines. The results are applied to the Tandem Mirror Experiment (TMX) and to the TMX Upgrade.