American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 54 / Number 2

A Simple Flow Analysis of Diffuser-Getter-Diffuser Systems

J. E. Klein, D. W. Howard

Fusion Science and Technology / Volume 54 / Number 2 / August 2008 / Pages 603-606

Technical Paper / Process Applications / dx.doi.org/10.13182/FST08-A1887

Tritium clean-up systems typically deploy gas processing technologies between stages of palladium-silver (Pd/Ag) diffusers/permeators. The number of diffusers positioned before and after a gas clean-up process to obtain optimal system performance will vary with feed gas inert composition. A simple method to analyze optimal diffuser configuration is presented. The method assumes equilibrium across the Pd/Ag tubes and system flows are limited by diffuser vacuum pump speeds preceding or following the clean-up process. A plot of system feed as a function of inert feed gas composition for various diffuser configuration allows selection of a diffuser configuration for maximum throughput based on feed gas composition.