American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 51 / Number 2T

Development of a Thermal Probe Method for Heat Flux and Ion Temperature Measurement in the Divertor Simulator MAP-II

K. Kurihara, S. Kado, H. Matsuura, T. Shikama, Y. Iida, K.-S. Chung, S. Tanaka (19P13)

Fusion Science and Technology / Volume 51 / Number 2T / February 2007 / Pages 250-252

Technical Paper / Open Magnetic Systems for Plasma Confinement / dx.doi.org/10.13182/FST07-A1365

The thermal probe method is capable of measuring ion temperature using the heat flow from plasma (Qplasma) versus the bias voltage (Vp) characteristic. Considering the heat transition phenomenon in the probe, we designed the thermal probe in order to obtain the Qplasma-Vp as well as the Ip-Vp characteristics. We performed a preliminary experiment of the thermal probe measurement in the divertor simulator MAP-II, and discuss the results and the assignments of the thermal probe method.