American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 60 / Number 1

High Temperature Operation of LiPb Loop

K. Noborio, Y. Yamanoto, C. Park, Y. Takeuchi, S. Konishi

Fusion Science and Technology / Volume 60 / Number 1 / July 2011 / Pages 298-302

In-Vessel Components - FW, Blanket, Shield & VV / Proceedings of the Nineteenth Topical Meeting on the Technology of Fusion Energy (TOFE) (Part 1) / dx.doi.org/10.13182/FST10-323

By introducing an induction heater and combination of a compact heat exchanger and a helium loop as a cooler, high temperature operation of lithium-lead loop at Kyoto University was performed successfully. After modification of thermal insulation, reasonable temperature distribution was obtained and sufficient effective heating power of 2.7kW and heating efficiency of 40% was demonstrated without concern about overheating of downstream of the high temperature section. As a result, observed highest temperature is 926°C and 4 hours continuous operation above 900°C was achieved.